Chapter 9 The toplevel system (ocaml)
This chapter describes the toplevel system for OCaml, that permits
interactive use of the OCaml system
through a read-eval-print loop. In this mode, the system repeatedly
reads OCaml phrases from the input, then typechecks, compile and
evaluate them, then prints the inferred type and result value, if
any. The system prints a # (sharp) prompt before reading each
phrase.
Input to the toplevel can span several lines. It is terminated by ;; (a
double-semicolon). The toplevel input consists in one or several
toplevel phrases, with the following syntax:
A phrase can consist of a definition, like those found in
implementations of compilation units or in struct … end
module expressions. The definition can bind value names, type names,
an exception, a module name, or a module type name. The toplevel
system performs the bindings, then prints the types and values (if
any) for the names thus defined.
A phrase may also consist in a value expression
(section 6.7). It is simply evaluated
without performing any bindings, and its value is
printed.
Finally, a phrase can also consist in a toplevel directive,
starting with # (the sharp sign). These directives control the
behavior of the toplevel; they are listed below in
section 9.2.
Unix:
The toplevel system is started by the command ocaml, as follows:
ocaml options objects # interactive mode
ocaml options objects scriptfile # script mode
options are described below.
objects are filenames ending in .cmo or .cma; they are
loaded into the interpreter immediately after options are set.
scriptfile is any file name not ending in .cmo or .cma.If no scriptfile is given on the command line, the toplevel system
enters interactive mode: phrases are read on standard input, results
are printed on standard output, errors on standard error. End-of-file
on standard input terminates ocaml (see also the #quit directive
in section 9.2).
On start-up (before the first phrase is read), if the file
.ocamlinit exists in the current directory,
its contents are read as a sequence of OCaml phrases
and executed as per the #use directive
described in section 9.2.
The evaluation outcode for each phrase are not displayed.
If the current directory does not contain an .ocamlinit file, but
the user’s home directory (environment variable HOME) does, the
latter is read and executed as described below.
The toplevel system does not perform line editing, but it can
easily be used in conjunction with an external line editor such as
ledit, ocaml2 or rlwrap
(see the
Caml Hump).
Another option is to use ocaml under Gnu Emacs, which gives the
full editing power of Emacs (command run-caml from library inf-caml).
At any point, the parsing, compilation or evaluation of the current
phrase can be interrupted by pressing ctrl-C (or, more precisely,
by sending the INTR signal to the ocaml process). The toplevel
then immediately returns to the # prompt.
If scriptfile is given on the command-line to ocaml, the toplevel
system enters script mode: the contents of the file are read as a
sequence of OCaml phrases and executed, as per the #use
directive (section 9.2). The outcome of the
evaluation is not printed. On reaching the end of file, the ocaml
command exits immediately. No commands are read from standard input.
Sys.argv is transformed, ignoring all OCaml parameters, and
starting with the script file name in Sys.argv.(0).
In script mode, the first line of the script is ignored if it starts
with #!. Thus, it should be possible to make the script
itself executable and put as first line #!/usr/local/bin/ocaml,
thus calling the toplevel system automatically when the script is
run. However, ocaml itself is a #! script on most installations
of OCaml, and Unix kernels usually do not handle nested #!
scripts. A better solution is to put the following as the first line
of the script:
#!/usr/local/bin/ocamlrun /usr/local/bin/ocaml
Windows:
In addition to the text-only command ocaml.exe, which works exactly
as under Unix (see above), a graphical user interface for the
toplevel is available under the name ocamlwin.exe. It should be
launched from the Windows file manager or program manager.
This interface provides a text window in which commands can be entered
and edited, and the toplevel responses are printed.
9.1 Options
The following command-line options are recognized by the ocaml command.
- -absname
-
Force error messages to show absolute paths for file names.
- -I directory
-
Add the given directory to the list of directories searched for
source and compiled files. By default, the current directory is
searched first, then the standard library directory. Directories added
with -I are searched after the current directory, in the order in
which they were given on the command line, but before the standard
library directory.
If the given directory starts with +, it is taken relative to the
standard library directory. For instance, -I +labltk adds the
subdirectory labltk of the standard library to the search path.
Directories can also be added to the list once
the toplevel is running with the #directory directive
(section 9.2).
- -init file
-
Load the given file instead of the default initialization file.
The default file is .ocamlinit in the current directory if it
exists, otherwise .ocamlinit in the user’s home directory.
- -labels
-
Labels are not ignored in types, labels may be used in applications,
and labelled parameters can be given in any order. This is the default.
- -no-app-funct
-
Deactivates the applicative behaviour of functors. With this option,
each functor application generates new types in its result and
applying the same functor twice to the same argument yields two
incompatible structures.
- -noassert
-
Do not compile assertion checks. Note that the special form
assert false is always compiled because it is typed specially.
- -nolabels
-
Ignore non-optional labels in types. Labels cannot be used in
applications, and parameter order becomes strict.
- -noprompt
-
Do not display any prompt when waiting for input.
- -nopromptcont
-
Do not display the secondary prompt when waiting for continuation
lines in multi-line inputs. This should be used e.g. when running
ocaml in an emacs window.
- -nostdlib
-
Do not include the standard library directory in the list of
directories searched for source and compiled files.
- -ppx command
-
After parsing, pipe the abstract syntax tree through the preprocessor
command. The module Ast_mapper, described in
chapter ??, implements the external interface
of a preprocessor.
- -principal
-
Check information paths during type-checking, to make sure that all
types are derived in a principal way. When using labelled arguments
and/or polymorphic methods, this flag is required to ensure future
versions of the compiler will be able to infer types correctly, even
if internal algorithms change.
All programs accepted in -principal mode are also accepted in the
default mode with equivalent types, but different binary signatures,
and this may slow down type checking; yet it is a good idea to
use it once before publishing source code.
- -rectypes
-
Allow arbitrary recursive types during type-checking. By default,
only recursive types where the recursion goes through an object type
are supported.
- -safe-string
-
Enforce the separation between types string and bytes,
thereby making strings read-only. This will become the default in
a future version of OCaml.
- -short-paths
-
When a type is visible under several module-paths, use the shortest
one when printing the type’s name in inferred interfaces and error and
warning messages. Identifier names starting with an underscore _ or
containing double underscores __ incur a penalty of +10 when computing
their length.
- -stdin
-
Read the standard input as a script file rather than starting an
interactive session.
- -strict-sequence
-
Force the left-hand part of each sequence to have type unit.
- -strict-formats
-
Reject invalid formats that were accepted in legacy format
implementations. You should use this flag to detect and fix such
invalid formats, as they will be rejected by future OCaml versions.
- -unsafe
-
See the corresponding option for ocamlc, chapter 8.
Turn bound checking off on array and string accesses (the v.(i) and
s.[i] constructs). Programs compiled with -unsafe are therefore
slightly faster, but unsafe: anything can happen if the program
accesses an array or string outside of its bounds.
- -unsafe-string
-
Identify the types string and bytes,
thereby making strings writable. For reasons of backward compatibility,
this is the default setting for the moment, but this will change in a future
version of OCaml.
- -version
-
Print version string and exit.
- -vnum
-
Print short version number and exit.
- -w warning-list
-
Enable or disable warnings according to the argument warning-list.
See section 8.2 for the syntax of the argument.
- -warn-error warning-list
-
Mark as fatal the warnings enabled by the argument warning-list.
See section 8.2 for the syntax of the argument.
- -warn-help
-
Show the description of all available warning numbers.
- - file
-
Use file as a script file name, even when it starts with a
hyphen (-).
- -help or --help
-
Display a short usage summary and exit.
Unix:
The following environment variables are also consulted:
-
LC_CTYPE
- If set to iso_8859_1, accented characters (from the
ISO Latin-1 character set) in string and character literals are
printed as is; otherwise, they are printed as decimal escape sequences
(\ddd).
- TERM
- When printing error messages, the toplevel system
attempts to underline visually the location of the error. It
consults the TERM variable to determines the type of output terminal
and look up its capabilities in the terminal database.
- HOME
- Directory where the .ocamlinit file is searched.
9.2 Toplevel directives
The following directives control the toplevel behavior, load files in
memory, and trace program execution.
Note: all directives start with a # (sharp) symbol. This #
must be typed before the directive, and must not be confused with the
# prompt displayed by the interactive loop. For instance,
typing #quit;; will exit the toplevel loop, but typing quit;;
will result in an “unbound value quit” error.
-
General
-
-
#help;;
-
Prints a list of all available directives, with corresponding argument type
if appropriate.
- #quit;;
-
Exit the toplevel loop and terminate the ocaml command.
- Loading codes
-
- #cd "dir-name";;
-
Change the current working directory.
- #directory "dir-name";;
-
Add the given directory to the list of directories searched for
source and compiled files.
- #remove_directory "dir-name";;
-
Remove the given directory from the list of directories searched for
source and compiled files. Do nothing if the list does not contain
the given directory.
- #load "file-name";;
-
Load in memory a bytecode object file (.cmo file) or library file
(.cma file) produced by the batch compiler ocamlc.
- #load_rec "file-name";;
-
Load in memory a bytecode object file (.cmo file) or library file
(.cma file) produced by the batch compiler ocamlc.
When loading an object file that depends on other modules
which have not been loaded yet, the .cmo files for these modules
are searched and loaded as well, recursively. The loading order
is not specified.
- #use "file-name";;
-
Read, compile and execute source phrases from the given file.
This is textual inclusion: phrases are processed just as if
they were typed on standard input. The reading of the file stops at
the first error encountered.
- #mod_use "file-name";;
-
Similar to #use but also wrap the code into a top-level module of the
same name as capitalized file name without extensions, following
semantics of the compiler.
- Environment queries
-
-
#show_class class-path;;
-
- #show_class_type class-path;;
-
- #show_exception ident;;
-
- #show_module module-path;;
-
- #show_module_type modtype-path;;
-
- #show_type typeconstr;;
-
- #show_val value-path;;
-
Print the signature of the corresponding component.
- #show ident;;
-
Print the signatures of components with name ident in all the
above categories.
- Pretty-printing
-
- #install_printer printer-name;;
-
This directive registers the function named printer-name (a
value path) as a printer for values whose types match the argument
type of the function. That is, the toplevel loop will call
printer-name when it has such a value to print.
The printing function printer-name should have type
Format.formatter -> t -> unit, where t is the
type for the values to be printed, and should output its textual
representation for the value of type t on the given formatter,
using the functions provided by the Format library. For backward
compatibility, printer-name can also have type
t -> unit and should then output on the standard
formatter, but this usage is deprecated.
- #print_depth n;;
-
Limit the printing of values to a maximal depth of n.
The parts of values whose depth exceeds n are printed as ...
(ellipsis).
- #print_length n;;
-
Limit the number of value nodes printed to at most n.
Remaining parts of values are printed as ... (ellipsis).
- #remove_printer printer-name;;
-
Remove the named function from the table of toplevel printers.
- Tracing
-
-
#trace function-name;;
-
After executing this directive, all calls to the function named
function-name will be “traced”. That is, the argument and the
result are displayed for each call, as well as the exceptions escaping
out of the function, raised either by the function itself or by
another function it calls. If the function is curried, each argument
is printed as it is passed to the function.
- #untrace function-name;;
-
Stop tracing the given function.
- #untrace_all;;
-
Stop tracing all functions traced so far.
- Compiler options
-
-
#labels bool;;
-
Ignore labels in function types if argument is false, or switch back
to default behaviour (commuting style) if argument is true.
- #ppx "file-name";;
-
After parsing, pipe the abstract syntax tree through the preprocessor
command.
- #principal bool;;
-
If the argument is true, check information paths during
type-checking, to make sure that all types are derived in a principal
way. If the argument is false, do not check information paths.
- #rectypes;;
-
Allow arbitrary recursive types during type-checking. Note: once
enabled, this option cannot be disabled because that would lead to
unsoundness of the type system.
- #warn_error "warning-list";;
-
Treat as errors the warnings enabled by the argument and as normal
warnings the warnings disabled by the argument.
- #warnings "warning-list";;
-
Enable or disable warnings according to the argument.
9.3 The toplevel and the module system
Toplevel phrases can refer to identifiers defined in compilation units
with the same mechanisms as for separately compiled units: either by
using qualified names (Modulename.localname), or by using
the open construct and unqualified names (see section 6.3).
However, before referencing another compilation unit, an
implementation of that unit must be present in memory.
At start-up, the toplevel system contains implementations for all the
modules in the the standard library. Implementations for user modules
can be entered with the #load directive described above. Referencing
a unit for which no implementation has been provided
results in the error Reference to undefined global `...'.
Note that entering open Mod merely accesses the compiled
interface (.cmi file) for Mod, but does not load the
implementation of Mod, and does not cause any error if no
implementation of Mod has been loaded. The error
“reference to undefined global Mod” will occur only when
executing a value or module definition that refers to Mod.
9.4 Common errors
This section describes and explains the most frequently encountered
error messages.
- Cannot find file filename
-
The named file could not be found in the current directory, nor in the
directories of the search path.
If filename has the format mod.cmi, this
means you have referenced the compilation unit mod, but its
compiled interface could not be found. Fix: compile mod.mli or
mod.ml first, to create the compiled interface mod.cmi.
If filename has the format mod.cmo, this
means you are trying to load with #load a bytecode object file that
does not exist yet. Fix: compile mod.ml first.
If your program spans several directories, this error can also appear
because you haven’t specified the directories to look into. Fix: use
the #directory directive to add the correct directories to the
search path.
- This expression has type t1, but is used with type t2
-
See section 8.4.
- Reference to undefined global mod
-
You have neglected to load in memory an implementation for a module
with #load. See section 9.3 above.
9.5 Building custom toplevel systems: ocamlmktop
The ocamlmktop command builds OCaml toplevels that
contain user code preloaded at start-up.
The ocamlmktop command takes as argument a set of .cmo and .cma
files, and links them with the object files that implement the OCaml toplevel.
The typical use is:
ocamlmktop -o mytoplevel foo.cmo bar.cmo gee.cmo
This creates the bytecode file mytoplevel, containing the OCaml toplevel
system, plus the code from the three .cmo
files. This toplevel is directly executable and is started by:
./mytoplevel
This enters a regular toplevel loop, except that the code from
foo.cmo, bar.cmo and gee.cmo is already loaded in memory, just as
if you had typed:
#load "foo.cmo";;
#load "bar.cmo";;
#load "gee.cmo";;
on entrance to the toplevel. The modules Foo, Bar and Gee are
not opened, though; you still have to do
open Foo;;
yourself, if this is what you wish.
9.6 Options
The following command-line options are recognized by ocamlmktop.
- -cclib libname
-
Pass the -llibname option to the C linker when linking in
“custom runtime” mode. See the corresponding option for
ocamlc, in chapter 8.
- -ccopt option
-
Pass the given option to the C compiler and linker, when linking in
“custom runtime” mode. See the corresponding option for
ocamlc, in chapter 8.
- -custom
-
Link in “custom runtime” mode. See the corresponding option for
ocamlc, in chapter 8.
- -I directory
-
Add the given directory to the list of directories searched for
compiled object code files (.cmo and .cma).
- -o exec-file
-
Specify the name of the toplevel file produced by the linker.
The default is a.out.